Part 3 maintenance – IAI America REXT User Manual
Page 400
![background image](/manuals/350365/400/background.png)
0
Part 3 Maintenance
Chapter 1 T
roubleshooting
368
Part 3 Maintenance
1.3.3 Messages Displayed during Operation Using the Teaching Pendant or PC Software
This section explains the warning messages that may be displayed during operation using the teaching pendant or PC
software.
Code
Message
Description
112
Invalid data
An invalid value was input in a parameter.
(Example) 9601 was input as the serial communication speed by mistake.
Input an appropriate value again.
113
Value too small
The input value is smaller than the setting range.
114
Value too large
The input value is larger than the setting range.
Refer to the actuator specifications or parameter table and input an appropriate value
again.
115
Home return not
completed
The current position was written when home return was not yet completed.
Execute home return again.
117
No movement
data
Target position is not set under the selected position number.
Input the target position first.
11E Unmatched
paired data
The values indicating the magnitude relationship of a pair of data are inappropriate.
(Example) The same value was input in both the parameters for soft limits + and –.
Input appropriate values again.
11F Absolute position
too small
The minimum movement toward the target position is determined by the lead length of the
drive system and resolution of the encoder.
This message indicates that the input target value is smaller than the minimum
movement.
(Example) If the lead length is 20 mm, the encoder’s resolution is 800 pulses and
accordingly the minimum movement becomes 20 y 800 = 0.025 mm/pulse.
In this case, this message will be displayed if 0.02 mm is input as the target
position.
121
Push & hold
search end over
The final position in push & hold operation exceeds the soft limit.
This has no negative effect if the actuator contacts the work part. If the actuator misses
the work part, however, the soft limit will be reached and thus this message is displayed.
Change either the target position or positioning band.
122
Multiple axes
connected at
assignment
An address was assigned when multiple axes were connected.
Assign each address only when one axis is connected.
180
Address change
OK
181
Controller
initialization OK
182
Home change all
clear
183
I/O function
changed
These messages are displayed to confirm operation.
(They do not indicate an operation error or other abnormality.)
202
Emergency stop This message indicates that an emergency stop has been actuated. (It does not indicate
an error.)
20A Servo off during
operation
This message indicates that the servo ON signal (SON) was turned OFF by the PLC while
the actuator was moving, and that the servo turned off and the movement was disabled as
a result.
-400-