Part 1 specification – IAI America REXT User Manual
Page 174
![background image](/manuals/350365/174/background.png)
Part 1 Specification
Chapter 3 Gateway R unit
150
Part 1 Specification
[Summary of Jogging Operation and Inching Operation]
With both jogging operation and inching operation, the JISL, JVEL, JOG+ and JOG- signals are used in combination.
The relationships of these signals are summarized in the table below.
Jogging operation
Inching operation
JISL
“0”
“1”
Speed
Parameter 26
Parameter 26
Travel distance
-
Parameter 48
JVEL = “0”
Acceleration/
deceleration
Rated value (The specific value varies
depending on the actuator.)
Rated value (The specific value varies
depending on the actuator.)
Speed
Parameter 47
Parameter 47
Travel distance
-
Parameter 49
JVEL = “1”
Acceleration/
deceleration
Rated value (The specific value varies
depending on the actuator.)
Rated value (The specific value varies
depending on the actuator.)
Condition for operation
Either the JOG+ or JOG- is “1”
Either the JOG+ or JOG- changes from “0”
to “1”
z
Actual Example of Jogging Operation (JOG+) (Axis 0)
Sent Query:
3F06F60B0110CF02
(JVEL = “0”, JISL = “0”)
Received Response: 3F06F60B0110CF02
z
Actual Example of Jogging Operation (JOG-) (Axis 0)
Sent Query:
3F06F60B0090CF32
(JVEL = “0”, JISL = “0”)
Received Response: 3F06F60B0090CF32
z
Actual Example of Inching Operation (JOG+) (Axis 0)
Sent Query:
3F06F60B0130CEDA
(JVEL = “0”, JISL = “1”)
Received Response: 3F06F60B0030CF4A
-174-