Part 1 Specification
Chapter 3 Gateway R unit
133
Part 1 Specification
[5] Monitor current speed – Axis (1)
z
Query
Field name
RTU mode data
(8 bits)
Data length
(bytes)
Remarks
Header
None
-
Slave address
3F H
1
Fixed.
Function code
03 H
1
Starting address
(upper)
F7 H
Starting address
(lower)
10 H
2
Address of the current speed data of axis (1)
Number of registers (upper)
00 H
Number of registers (lower)
01 H
2
Number of registers (1 register = 1 word): 1
Error check
(CRC)
Based on
calculation result
2
(B3 65)
Trailer
None
-
Total bytes
8
z
Response
Field name
RTU mode data
(8 bits)
Data length
(bytes)
Remarks
Header
None
-
Slave address
3F H
1
Fixed.
Function code
03 H
1
Data bytes
02 H
1
1-word register x 1 = 2 bytes
Data 1
(upper)
Arbitrary
Data 1
(lower)
Arbitrary
1 each for upper
and lower words
2
Current speed data
Error check
(CRC)
Based on
calculation result
2
Trailer
None
-
Total bytes
z
Actual Example
Sent Query:
3F03F7100001B365
Received Response: 3F030200009181
(Explanation) The current speed data is “0000H.”
In other words, the current speed is “0” in this example.
The current speed is indicated in units of 1.0 mm/sec.
The current speed is set as a multiple of 1.0 mm/sec or 0.1 mm/sec.
The unit is changed on the special parameter setting screen of the ROBONET gateway parameter
creation tool. (The unit change function is supported by tools of version 1.0.4.0 and later.)