Part 1 specification – IAI America REXT User Manual
Page 134
![background image](/manuals/350365/134/background.png)
Part 1 Specification
Chapter 3 Gateway R unit
110
Part 1 Specification
(3) Speed Change during Movement
The actuator can be controlled at multiple speeds in a single operation. In other words, the speed can be decreased or
increased at a given point.
However, a position data must be set for every point at which the speed is changed.
This function can be used in situations where the work part is made of soft material or is a bottle or has other
easy-to-topple shape and you don’t want the work part to receive vibration or impact upon stopping.
(Example) Positioning to position 2 (300 mm from the home), where the actuator is moved at a speed of 200 mm/sec to
intermediate position 1 (200 mm from the home) and at a speed of 20 mm/sec thereafter.
Example of Position Table
* Set an appropriate time so that “T1 t 0 ms” is satisfied, by considering the scan time of the host controller.
Position 1
Position 2
Position 1
Position 2
Position 1 Position 2 Position 3
Position
Speed
Acceleration Deceleration
Push
Positioning band
Comment
Position command
Position start
(CSTR)
Position complete
(PEND)
Moving (MOVE)
Actuator movement
Completed position
Speed
Position 1
Position 2
Position 1
Position 2
Position 1
Position 2
*
-134-