Scon/pcon-cf settings and signal assignments – IAI America REXT User Manual
Page 380

0
Part 2 Startup Chapter
Chapter 6 Setting for External SIO Link and Other
Part Startup Chapter
Chapter Setting for External SIO Link and Other
.
SCON/PCON-CF Settings and Signal Assignments
SCON controllers can be operated only in the positioner mode. They cannot be operated in the pulse-train input mode. For
SCON controllers, set the parameters as follows.
() User parameters
: Applicable
X: Not applicable
No.
Name
Description of setting (change)
SCON
PCON-CF
SIO baud rate
00 bps (Default)
Change to 000 bps.
Minimum delay for slave
transmitter activation
msec (Default)
Change to msec.
PIO pattern selection
Default: 0 (Standard type)
Set a value between 0 and . *
PIO power monitoring
Default: 0 (Enable)
Change to (Disable).
X
*
The maximum positions that can be registered varies depending on the mode.
() Piano switches (Limited to SCON controllers)
Set piano switch on the front panel of the SCON to the OFF position to change to the positioner mode.
() Mode selector switch
Set the mode selector switch on the front panel of the SCON/PCON-CF to MANU.
() Signal assignment
The assignment of each signal for the SCON/PCON-CF is the same as with the RPCON/RACON. Refer to “ROBONET
Specification.”
() Set the axis number using the rotary switches.