Part 1 specifications – IAI America REXT User Manual
Page 309

Part 1 Specifications
Network type
CC-Link
DeviceNet
PROFIBUS
EtherNet/IP
RS485SIO
Modbus
gateway mode
SIO through
mode
[7] Address
A value from 1 to
64 can be set.
(Normally 1
represents the
master unit.)
A value from 0 to
63 can be set.
(Normally 63
represents the
master unit.)
A value from
1 to 125 can
be set.
0.0.0.0 to
255.255.255.255
Fixed to 63.
-
[8] Baud rate
156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps
Set
automatically.
Set
automatically.
Set
automatically.
10 Mbps,
half-duplex
10 Mbps,
full-duplex
100 Mbps,
half-duplex
100 Mbps,
full-duplex
9.6 kbps
19.2 kbps
38.4 kbps
57.6 kbps
115.2 kbps
230.4 kbps
38.4 kbps
57.6 kbps
115.2 kbps
230.4 kbps
[10] Displayed
occupancy
information and
I/O sizes
(bytes)
-
Number of (positioner 1/simple direct mode) axes x 8 + Number of
direct numerical specification (positioning) mode axes x 16 + 16
Or,
Number of (positioner 2/solenoid valve mode 1/solenoid valve mode
2) axes x 4
-
P
ar
t 1
S
p
ec
if
ica
tion
Ch
apt
er
3
G
atew
a
y
R
u
n
it
-309-