Part 1 specification – IAI America REXT User Manual
Page 170
![background image](/manuals/350365/170/background.png)
Part 1 Specification
Chapter 3 Gateway R unit
146
Part 1 Specification
Jogging/Inching Switching Command (JISL)
This signal is used to switch jogging operation and inching operation.
JISL = “0”: Jogging operation
JISL = “1”: Inching operation
z
Query
Field name
RTU mode data
(8 bits)
Data length
(bytes)
Remarks
Header
None
-
Slave address
3F H
1
Fixed.
Function code
06 H
1
Starting address
(upper)
F6 H
Starting address
(lower)
0B H
2
Address of the control signal register of axis (0)
New data (data written) (upper)
Arbitrary
New data (data written) (lower)
Arbitrary
2
Used in combination with the JOG+/-, JVEL and
SON signals.
Error check
(CRC)
16 bits
2
Based on calculation result
Trailer
None
-
Total bytes
8
z
Response
If the data has been changed (written) successfully, the response is the same as the query.
z
Actual Example
Sent Query:
3F06F60B -----
Received Response: 3F06F60B -----
-170-