Part 1 specification, 2 led indicators – IAI America REXT User Manual
Page 216
![background image](/manuals/350365/216/background.png)
Part 1 Specification
Chapter 4 Controller Unit
192
Part 1 Specification
4.3.2 LED Indicators
These LEDs are used to monitor the status of the RACON/RPCON.
Symbol
Indicator color
Explanation
SV/ALM
Green/red
A steady green light comes on when the servo is ON, and changes to a steady read light
when an alarm is present.
TX/RX
Green /yellow A steady green light comes on while data is being sent over the communication line, and a
steady yellow light comes on while data is being received.
STATUS 3
Green
STATUS 2
Green
STATUS 1
Green
STATUS 0
Green
x
When the servo is ON o Indicate the monitored current
x
When an alarm is present o Indicate a simple alarm code
Details are explained below.
BK (RLS)
Yellow
A steady yellow light comes on while the brake is released, and the LED is off while the
brake is actuated.
Description of STATUS indicators
What these indicators indicate varies depending on whether or not the servo is ON and an alarm is present.
(1) When the servo is ON
When the servo is ON, the STATUS LEDs on the front panel can be used to roughly monitor the motor current. The
command current ratios (percentage ranges of the rated current) and corresponding LED indicator statuses are shown
below.
STATUS
Command current ratio
3 2 1 0
RPCON
RACON
{
{
{
{
0.00% to 6.24%
0.00% to 18.74%
{
{
{
z
6.25% to 24.99%
18.75% to 74.99%
{
{
z
z
25.00% to 49.00%
5.00% to 131.24%
{
z
z
z
50.00% to 74.99%
31.25% to 187.74%
z
z
z
z
75.00% to 100.00%
187.75% to 300.00%
{
indicates that the LED is off, while z indicates a steady green light.
(2) When the ALM signal is ON (an alarm is present)
When the ALM signal turns ON, the statuses of STATUS LEDs can be used to check the cause of the alarm. Since there
are only four LEDs, however, several causes are indicated by one indication pattern. Accordingly, you must connect the
PC software or teaching pendant to check the exact cause. Refer to “Alarm Indicator List” on the next page for the alarm
details, alarm codes and corresponding indicator statuses.
-216-