MTS MultiPurpose TestWare®
Creating Profiles
Model 793.11 Profile Editor
500
Channel Data Syntax
Following the channel definition, you must define the command data for that
channel.
Channel data attributes can be entered two ways—as constants or as individual
values. Constants are declared before any individual parameters are listed, and
they require the equal sign (=) to be appended to the end of its keyword. Any
keyword can be defined as a constant. The following is one example of the
command data syntax where one keyword is defined as a constant. Each row of
data defines a command element.
The following is an example of proper command data syntax:
Shape= Sine
Frequency
Count
Level1
Level2
Hz
Cycles
mm
mm
10
100
5
-5
5
150
10
0
1
0.5
0
0