The file is read in sequence (row by row) to produce a waveform:
Note
The first segment of each row is always a “transition” segment from the
end level in the previous row to Level 1 in the current row. At the
beginning of the procedure, the first segment is a transition from the
current level to Level 1 in Row 0.
About Creating Profiles
You create profiles by typing values into a grid, which defines custom or
arbitrary waveforms.
Certain elements of the profiles you create must match the same elements in the
station configurations (which you created with the Station Builder application)
on which you intend to play out the profiles. For instance, a profile’s control
modes, sensor ranges, and unit types must be compatible with the station
configuration, or you will not be able to run the profile on your test system.
Seg. 3 3
sec.
Seg. 3 4
sec.
Seg. 1 5
sec.
Seg. 2 5
sec.
Seg. 3 5
sec.
Seg. 1 4
sec.
Seg. 2 4
sec.
Seg. 2 3
sec.
Seg. 1 3
sec.
Transition segment
from zero to
Row 0, Level 1
Transition segment from
Row 0 end level to
Row 1, Level 1
Transition segment from
Row 1 end level to
Row 2, Level 1
Row 0
Row 1