MTS Series 793 Application User Manual
Page 361

Operator Event Process
MTS MultiPurpose TestWare®
Event Process Descriptions
361
Options tab
Options
Tab
I
TEM
D
ESCRIPTION
Trigger Mode
Trigger Once causes the process to generate a trigger and a done signal when
the specified operator event occurs.
Trigger Continuously causes the process to generate a trigger signal when the
specified operator event occurs. When you make this selection, the process
will only terminate upon an interrupt or when its parent group or procedure
ends.
Log Message As
Assigns a severity level to the message (in ascending levels of severity:
Diagnostic, Information, Warning, or Error) and makes the message
available to the MPT Specimen Log.
If the Station Manager Station Log and the Basic TestWare Test Log are
configured to accept messages from all sources, then MPT makes the message
available to them also.
Note
Unlike Station Manager and Basic TestWare, MPT does not generate
messages with a severity level of Fatal Error.
Each type of log will accept the message only if it has been configured to store
messages with the assigned severity level.
For instance, if the MPT Specimen Log is configured to accept messages with
a minimum severity level of Warning, and you assign Information as the
severity level for this message, then this message will not be recorded in the
MPT Specimen Log. In that instance the MPT Specimen Log would accept
messages having only Warning and Error severity levels.
You can specify the minimum severity level that each type of log will accept.
To do this:
•
For MultiPurpose TestWare, select the MPT Options Editor, then
select the Specimen Log tab.
•
For Station Manager, select Tools, then select Station Options, then
select the Station Log tab.
•
For Basic TestWare, select Test Setup, then select the Test Log tab.