MTS Series 793 Application User Manual
Page 468

MTS MultiPurpose TestWare®
Model 793.14 Fatigue Monitoring Application
Trend and Fatigue Monitoring Applications
468
Controls
The Fatigue Monitoring main window controls are described in the following
table.
Fatigue Monitoring Window
I
TEM
D
ESCRIPTION
Displays the Numerical Display window.
Displays the Limit Settings window.
Shows or hides the channel value information.
Active Process
Selects the process or file to view. You can have multiple processes or multiple
files per window.
Lifetime Data
Displays “percentage of lifetime” instead of damage number.
Channel Selection
Specifies the damage value plotted for a particular signal. Up to six different
values can be plotted at the same time.
•
Clicking the Pass/Acc. button at the head of a column selects the top six
values in that column.
•
Clicking on the channel name selects all damage values for this channel.
•
To select values randomly (for example, Channel 1 BC Pass and Channel
2 WC Acc), press the Ctrl key while clicking on the check boxes.