2 write, Write, External device setup manual – IDEC High Performance Series User Manual
Page 598
Chapter 4
580
External Device Setup Manual
7.2
Write
This command is used by the external device to write data to the MICRO/I or Touch data memory. One command can write a maxi-
mum of 255 words of data.
7.2.1
Command
Format
Detailed description
Command
Code
Description
Bytes
ENQ
05h
Command start
1
W
57h
Write Command
1
DM Address
DM address to begin writing from
This is expressed as the ASCII code of the hexadecimal value of the address.
4
Words
Number of words to write
The hexadecimal value expressed using ASCII code.
2
Data
DM ADDRESS DATA.
The hexadecimal value expressed using ASCII code.
The words are in order from the lowest address.
4 x N
N is the number of
words
BCC
Only required when 'with BCC' is set.
Exclusive OR (HEX) from ENQ to before BCC converted to ASCII code.
2
CR
0Dh
End
1