1 idec, 1 connection table, Idec – IDEC High Performance Series User Manual
Page 42: Connection table, 1idec, External device setup manual
Chapter 2
24
External Device Setup Manual
1
IDEC
Selecting OpenNet (FC3A) or MicroSmart (FC4A/FC5A) as the Host I/F Driver allows the user to use the 1: N Communication and
Pass-through function. Selecting Web Server Unit (FC3A/FC4A/FC5A) as the Host I/F Driver allows the user to use 1: N Communi-
cation.
•
Pass-through function (Refer to “Pass-Through Function” in the WindO/I-NV2 User’s Manual)
•
1: N Communication function (Refer to Chapter 6 "1: N Communication (Multi-drop)" on page 627)
1.1
Connection Table
1.1.1
Compatible PLCs
Series Name
System
(CPU unit)
Link unit
WindO/I-NV2 Settings
Interface
Flow
Control
Host I/F Driver
OpenNet Controller
FC3A-CP2
Not required
(connects to CPU unit)
RS232C
Connection Diagram 1
(refer to P37)
Hardware
OpenNet(FC3A),
MicroSmart
(FC4A/FC5A)
RS422/485 2-wire
Connection Diagram 2
(refer to P40)
Web Server Unit
(FC4A-SX5ES1E)
Ethernet
-
Web Server Unit
(FC3A/FC4A/FC5A)
MICROSmart
*1
FC4A-C10R2
Not required
(connects to CPU unit)
RS232C
Connection Diagram 3
(refer to P43)
Hardware
OpenNet(FC3A),
MicroSmart
(FC4A/FC5A)
RS232C
Connection Diagram 1
(refer to P37)
None
Web Server Unit
(FC4A-SX5ES1E)
Ethernet
-
Web Server Unit
(FC3A/FC4A/FC5A)