When motion commands are not used, When motion commands are used – Yaskawa MP920 Motion Module User Manual
Page 65

2.3 Position Control
2-39
2
When Motion Commands Are Not Used
When motion commands are not used, the Speed Reference Selection Flags are disabled,
and the speed-related parameters have the meanings shown in the following table.
When Motion Commands Are Used
When motion commands are used, the meanings of the speed-related parameters differ
according to the Speed Reference Selection (bit 13 of OW01).
Parameter No.
Name
Description
Bit 3 of OW01
Speed Reference Value
Selection
Invalid
OW0A
Approach Speed Setting
Specified as a percentage (%) of the rated
speed.
OW0B
Creep Speed Setting
Specified as a percentage (%) of the rated
speed.
OW15
Speed Reference Setting
The rapid traverse speed is specified as a per-
centage (%) of the rated speed.
OL22
Rapid Traverse Speed
Invalid
OW2C
Override
Invalid
Bit 13 of
OW01
Parameter
No.
Name
Description
0
OW0A
Approach Speed Setting
Specified using the reference unit.
OW0B
Creep Speed Setting
Specified using the reference unit.
OW15
Speed Reference Setting
Invalid
OL22
Rapid Traverse Speed
Specified using the reference unit.
OW2C
Override
Valid
1
OW0A
Approach Speed Setting
Specified as a percentage (%) of the
rated speed.
OW0B
Creep Speed Setting
Specified as a percentage (%) of the
rated speed.
OW15
Speed Reference Setting
The rapid traverse speed is specified
as a percentage (%) of the rated
speed.
OL22
Rapid Traverse Speed
Invalid
OW2C
Override
Valid