3 parameter settings, Overtravel input signal on/off settings, Sgdm and sgds servopacks – Yaskawa MP920 Motion Module User Manual
Page 392: Sgda and sgdb servopacks

9 Application Precautions
9.2.3 Parameter Settings
9-12
9.2.3
Parameter Settings
Overtravel Input Signal ON/OFF Settings
Set the following parameters to switch between overtravel input signal ON and OFF opera-
tion.
SGDM and SGDS SERVOPACKs
Note: We recommend the shaded settings.
SGDA and SGDB SERVOPACKs
Note: We recommend the shaded settings.
Parameter No.
Description
Setting
Meaning
Factory
Setting
Pn50A.4
P-OT signal mapping
2
Uses the P-OT (forward run prohibited)
input signal.
(Forward run prohibited when open, and
forward run permitted at 0V.)
2
8
Fixed the signal to invalid.
Pn50B.1
N-OT signal mapping
3
Uses the N-OT (reverse run prohibited)
input signal.
(Reverse run prohibited when open, and
reverse run permitted at 0V.)
3
8
Fixed the signal to invalid.
Parameter No.
Description
Setting
Meaning
Factory
Setting
Cn-01
Bit 2
P-OT input signal ON
(Use)/OFF (Not use)
0
Uses the P-OT (forward run prohibited)
input signal.
(Forward run prohibited when open, and
forward run permitted at 0V.)
0
1
Does not use the P-OT (forward run pro-
hibited) input signal.
(Forward run always permitted.)
Cn-01
Bit 3
N-OT input signal ON
(Use)/OFF (Not use)
0
Uses the N-OT (reverse run prohibited)
input signal.
(Reverse run prohibited when open, and
reverse run permitted at 0V.)
0
1
Does not use the N-OT (reverse run pro-
hibited) input signal.
(Reverse run always permitted.)