2.2 Control Modes
2-23
2
1. Set the motion fixed parameters according to the user’s machine.
* 1. Valid only with an SVB-01A Module.
* 2. Valid only with an SVA-02A Module.
2. Set the motion parameters.
The following three methods can be used to set the motion setting parameters.
• Using the MPE720 Setting Parameter Window
• Using a ladder logic program
• Using a motion program
Table 2.7 Examples of Fixed Parameters
No.
Name
Setting Range
Meaning
Setting
Example
7
Rated Motor Speed Setting
1 to 32000
Rated motor speed
3000 min
-1
8
Number of Feedback Pulses per
Motor Rotation
4 to 65532
Number of pulses
before multiplication
2048
9
D/A Output Voltage at 100%
Speed
0.001 to 10.000
0.001 = 0.001 V
1 = 1 V
6.000 V
Feedback Pulses per Motor
Rotation (For high-resolution)
*1
4 to 2147483647
1 = 1 pulse/rev
2048 pulses/
rev
10
D/A Output Voltage at 100%
Torque Limit
*2
0.001 to 10.000
0.001 = 0.001 V
1 = 1 V
3.000 V
Table 2.8 Examples of Setting Parameters
Name
Register No.
Setting
Range
Meaning
Setting
Example
Positive Torque Limit
Setting (TLIMP)*
OW02
-327.68 to
327.67
0.01 = 0.01%
1 = 1%
-100.00
(-100.00%)
Positive Speed Limit-
er Setting (NLIMP)
OW04
0.00 to
327.67
0.01 = 0.01%
1 = 1%
130.00
(130.00%)
Negative Speed Lim-
iter Setting (NLIMN)
OW05
0.00 to
327.67
0.01 = 0.01%
1 = 1%
130.00
(130.00%)
Zero Point Offset
(ABSOFF)
OW06
-2
31
to 2
31
-1
1 = 1 reference unit
With pulse: 1 = 1 pulse
100 pulses
Approach Speed
Setting (NAPR)
OW0A
0 to 32767
Value (%) for rated speed: 1
= 0.01%
2000
(20.00%)
Creep Speed Setting
(NCLP)
OW0B
0 to 32767
Value (%) for rated speed: 1
= 0.01%
1000
(10.00%)
Linear Acceleration
Time Constant
(NACC)
OW0C
0 to 32767
Linear acceleration time con-
stant (ms) at speed pattern
generation
1000
(1 second)
Linear Deceleration
Time Constant
(NDEC)
OW0D
0 to 32767
Linear deceleration time
constant (ms) at speed pat-
tern generation
1000
(1 second)
Positioning Complet-
ed Range Setting
(PEXT)
OW0E
0 to 65535
1 = 1 reference unit
With pulse: 1 = 1 pulse
10 pulses
Error Count Alarm
Detection Setting
(EOV)
OW0F
0 to 65535
1 = 1 reference unit
With pulse: 1 = 1 pulse
65535 pulses