8 Troubleshooting
8.1.1 Description of Motion Alarms
8-4
SVB-01
Servo Drive alarm code
(SVALARM)
IW
24
Run Status (RUNSTS)
IW
00
Bit1: PRMERR
Motion setting parameter setting error
Bit2: FPRMERR
Motion fixed parameter setting error
Out of range parameter number (ERNO)
W
0F
Alarms (ALARM)
IL
22
Bit0: SVERROR Servopack error
Bit1: OTF
Positive overtravel
Bit2: OTR
Negative overtravel
Bit3: SOTF
Positive software limit
Bit4: SOTR
Negative software limit
Bit5: SVOFF
Servo power OFF
Bit17: ABSOVER ABS encoder count exceeded
00: Absolute data error
02: Parameter
destruction
10: Overcurrent
11: Ground
fault
F3: Power
loss
Motion program alarms
Alarm output status
specified from the Group
Definitions Window
Program alarms
2h: Zero division error
10h:
Circumference
specified
for
radius
specification
11h: Interpolation feed speed exceeded
12h:
No
interpolation
feed
speed
20h: REG data error
Axis alarms
80h: Logical axis use disabled
81h: POSMAX exceeded in infinite length
aixs
designation
82h: Distance the axis moved exceeded
LONG_MAX
89h:
Beyond
the
ACC/SCC/DCC
setting
range
Displays the execute/error status of Motion
Modules: 7-segment LED indicator