Yaskawa MP920 Motion Module User Manual
Page 139

4.2 Parameter List by Module
4-19
4
9
Machine Coor-
dinate System
Feedback Posi-
tion (APOS)
IL08
-2
31
to 2
31
-1
1 = 1 reference unit
(1 = 1 pulse for pulse unit)
Note: Will not be updated if the machine is
locked.
√
√
√
−
11
Position Error
(PERR)
IL0A
-2
31
to 2
31
-1
1 = 1 pulse
√
√
−
−
13
Speed Refer-
ence Output
Monitor
(SPDREF)
IW0C
-32768 to 32767
1 = 0.01%
√
√
−
−
14
Speed Monitor
(NFB)
IW0D
-32768 to 32767
1 = 0.01%
−
√
−
−
15
Not used.
IW0E
−
−
−
−
−
−
16
Out of Range
Parameter
Number
(ERNO)
IW0F
1 to 63
101 to 148
Motion setting parameter error number
Motion fixed parameter error number + 100
√
√
√
√
17
Cumulative
Rotations from
Absolute
Encoder
(ABSREV)
IL10
0 to
±99999
1 = 1 rotation
√
√
−
−
19
Initial Incremen-
tal Pulses from
Absolute
Encoder
(IPULSE)
IL12
-2
31
to 2
31
-1
1 = 1 pulse
√
√
−
−
21
Motion Com-
mand Response
Code
(MCMD-
RCODE)
IW14
0 to 65535
Motion command that is currently executing.
(Refer to OW20 for details.)
√
√
√
√
22
Motion
Command
Status
(MCMDSTS)
IW15
Bit 0: BUSY
Command Executing Flag
√
√
√
√
Bit 1: HOLDL
Command Hold Completed
√
√
√
√
Bit 2: DEN
Distribution Completed
√
√
√
√
Bit 3: ZSET
Zero Point Setting Completed
√
√
√
√
Bit 4: EX_LATCH
External Positioning Signal Latched
√
√
√
−
Bit 5: FAIL
Command Error End
√
√
√
√
Bit 6: ZRNC
Zero Point Return Completed
√
√
√
√
Bits 7 to 15
Not used.
−
−
−
−
23
Number of Dig-
its Below
Decimal Point
Monitor
(DECNUMM)
IW16
0 to 5
Copies motion fixed parameter Number of Dig-
its Below Decimal Point.
√
√
√
√
Table 4.4 Motion Monitoring Parameters (cont’d)
No.
Name
Register
Number
Setting Range
(Bit Name)
Meaning
Remarks
SVA
-01A
SVA
-02
A
SVB
-01
PO-
01