Yaskawa MP920 Motion Module User Manual
Page 289

6 SVB Module Specifications and Handling
6.2.5
Σ-II Series SERVOPACK Parameters
6-54
Torque-related
Parameters
(cont’d)
Pn406
Emergency Stop Torque
2
%
0 to 800
800
Pn407
Reserved
2
min
-1
0 to 10000
10000
Pn408
Torque Function Switches
2
−
−
0000
Pn409
Notch Filter Frequency
2
Hz
50 to 2000
2000
Sequence-
related
Parameters
Pn500
Positioning Completed Width
2
reference unit
0 to 250
7
Pn501
Reserved
2
min
-1
0 to 10000
10
Pn502
Rotation Detection Level
2
min
-1
1 to 10000
20
Pn503
Reserved
2
min
-1
0 to 100
10
Pn504
NEAR Signal Width
2
reference unit
1 to 250
7
Pn505
Overflow Level
2
256 reference
units
1 to 32767
1024
Pn506
Brake Reference - Servo OFF Delay
Time
2
10 ms
0 to 50
0
Pn507
Brake Reference Output Speed Level
2
min
-1
0 to 10000
100
Pn508
Timing for Brake Reference Output
during Motor Operation
2
10 ms
10 to 100
50
Pn509
Momentary Hold Time
2
ms
20 to 1000
20
Pn50A
Input Signal Selections 1
*3
2
−
−
2881
Pn50B
Input Signal Selections 2
*3
2
−
−
8883
Pn50C
Reserved
2
−
−
8888
Pn50D
Reserved
2
−
−
8888
Pn50E
Output Signal Selections 1
2
−
−
3211
Pn50F
Output Signal Selections 2
2
−
−
0000
Pn510
Output Signal Selections 3
2
−
−
0000
Pn511
Output Signal Selections 5
*3
2
−
−
6541
Pn512
Output Signal Reversal Settings
2
−
−
0000
Other
Parameters
Pn600
Regenerative Resistor Capacity
*4
2
10 W
Depends on
SERVO-
PACK
capacity.
*5
0
Pn601
Reserved
2
−
Depends on
SERVO-
PACK
capacity.
*5
0
Transmission
Parameters
Pn800
Communications Control
2
−
−
0000
Sequence-
related
Pn801
Function Selection Application
Switches 6
2
−
−
0003
Pn802
Command Masks
2
−
−
0000
Pn803
Origin Range
2
reference unit
0 to 250
10
(cont’d)
Classification
Parameter
No.
Name
Size
(bytes)
Units
Setting
Range
Factory