Yaskawa MP920 Motion Module User Manual
Page 147

5.1 SVA-01A Module
5-5
5
Serious fault
A two-digit error code appears following F.
Examples:
F
→ 0 → 1: Watchdog time over
F
→ 0 → 2: Synchronization error
F
→ 4 → 1: ROM diagnosis error
F
→ 4 → 2: RAM diagnosis error
F
→ 4 → 3: Shared memory diagnosis error
F
→ 4 → 4: CPU built-in timer error
F
→ 4 → 5: Timer diagnosis error
F
→ 4 → 6: NVRAM read error
F
→ 4 → 7: NVRAM write error
F
→ 4 → 8: General illegal instruction interruption
occurrence
F
→ 4 → 9: Slot illegal instruction interruption occurrence
F
→ 5 → 0: CPU address error interruption occurrence
F
→ 5 → 1: DMA address error interruption occurrence
F
→ 5 → 2: User break interruption occurrence
F
→ 5 → 3: Trap instruction interruption occurrence
F
→ 5 → 4: MPD71054 diagnosis error
Axis 1
Alarm
(SVRDY “ON”)
Abnormal
(SVRDY “OFF”)
Classifies failures into “alarm” or “abnormal” according to
the value of “IW00 + axis offset.” Check for the follow-
ing errors.
• Alarm
Deviation error
Parameter setting error
• Abnormal
Fixed parameter setting error
Absolute encoder I/F error
Axis 2
Axis 3
Axis 4
Operation of
other CPU
stops
Indicates other Modules that do not operate. For example,
CPU Module is in STOP status.
Absolute posi-
tion reading
retry status
Indicates retrying of absolute position reading by turning ON
the power and resetting from the start, in the case of setting
absolute encoder for fixed parameter encoder.
Display
Category
Meaning
or
followed by error code