Yaskawa MP920 Motion Module User Manual
Page 274

6.2 SVB-01 Parameters
6-39
6
3
Calculated
Position in
Machine
Coordinate
System
(CPOS)
IL02
-2
31
to 2
31
-1
Indicates the calculated position in a machine coordinate system con-
trolled by SVB Modules.
5
Not used.
IL04
−
−
7
Machine
Coordinate
System Latch
Position
(LPOS)
IL06
-2
31
to 2
31
-1
Indicates the latch position in a machine coordinate system controlled
by SVB-01 Modules. It is refreshed when Motion Command Code
(OW20) is set to 1 (External Positioning) or 6 (Interpolation with
Position Detection Function) and latching is completed.
1 = 1 reference unit (when specified as pulse units: 1 = 1 pulse)
9
Machine Coor-
dinate System
Feedback Po-
sition (APOS)
IL08
-2
31
to 2
31
-1
Indicates the feedback position in a machine coordinate system con-
trolled by SVB-01 Modules.
1 = 1 reference unit (when specified as pulse units: 1 = 1 pulse)
Note: The parameter value is not refreshed during machine lock.
11 to
15
Not used.
IL0A to
IW0E
−
−
16
Out of Range
Parameter
Number
(ERNO)
IW0F
• Motion
setting
parameter
1 to 64
• Motion fixed
parameter
101 to 148
Indicates the most recent setting parameter number that exceeded the
range in OW00 to OW3F motion setting parameter or motion
fixed parameter settings.
• Motion setting parameters: 1 to 64
• Motion fixed parameters: 101 to 148
17 to
20
Not used.
IW10 to
IW13
−
−
21
Motion
Command
Response
Code (MCMD-
RCODE)
IW14
0 to 65535
Indicates the OW20: Motion Command Code that is currently
executing. Refer to OW20 for details on motion commands.
22
Motion
Command
Status
(MCMDSTS)
IW15
Monitors the executing status of an OW20: Motion Command Code. The bit configu-
ration is described below.
Bit 0
Command
Executing Flag
(BUSY)
Indicates the motion command status. This bit is used for abort status.
0: READY (completed)
1: BUSY (processing)
Bit 1
Command Hold
Completed Flag
(HOLDL)
Turns ON when a HOLD is completed. Refer to individual motion
functions for details on the HOLD function.
Bit 2
Distribution
Completed
(DEN)
Turns ON when the amount of movement cleared is completed.
Bit 3
Zero Point Set-
ting Completed
(ZSET)
Turns ON when the zero point setting (ZSET) has been executed by
OW20: Motion Command Code. It also turns ON when bit 3 of
IW17: ABS System Infinite Length Position Control Data Load
Request has finished execution.
Table 6.4 Motion Monitoring Parameters (cont’d)
No.
Name
Register
Number
Setting Range/
Bit Name
Description