WCC III Technical Guide

15-2

15. SAT 3C/D/F INSTALLATION

SAT 3C/D/F Benefits and Features

SAT 3C/D/F CONTROLLER VERSES SAT 2C/D CONTROLLER BENEFITS

THE SAT 3C/D/F CONTROLLER HAS A SMALLER MECHANICAL FOOT PRINT THAN THE OLD SAT 2C/D CONTROLLER

THE SAT 3C/D/F CONTROLLER USES THE SAME WIRING AS THE SAT 2C/D CONTROLLER

THE SAT 3C/D CONTROLLER USES THE SAME TUC AND RTU COMMUNICATION PROTOCOL AS THE SAT 2C/D CONTROLLER -
SO IN THEORY, A TUC OR RTU CHANGE OUT IS NOT REQUIRED WHEN CHANGING A SAT 2C/D CONTROLLER TO A SAT 3C/D

CONTROLLER. BUT MUCH BETTER CONTROL IS GENERALLY POSSIBLE WITH THE NEWER WCC III BASED TUC/RTU SOFTWARE.

THE SAT 3C/D/F CONTROLLER USES THE SAME SATELLITE DATA FILES AS THE SAT 2C/D CONTROLLER

THE SAT 3C/D/F CONTROLLER PROGRAM UPDATES ARE AVAILABLE VIA A "FLASH" PROGRAMMING OR A DOWNLOADED

UPDATE. THE SAT 2C/D CONTROLLER SOFTWARE UPDATES HAD TO BE CHANGED OUT WITH A EPROM. THE SAT 3C/D/F

CONTROLLER CAN BE CHANGED BY REMOTELY DOWNLOADING THE SOFTWARE OR BY "FLASHING" A NEW PROGRAM

INTO THE SAT 3 D

CONTROLLER'S MEMORY. A FLASH

C/ /F

PROGRAMMING TOOL IS AVAILABLE TO THE CONTRACTOR.

BOTH USB AND PARALLEL PORT VERSIONS OF THE FLASH PROGRAMMING TOOL ARE AVAILABLE.

ADDED SAT 3C/D/F CONTROLLER FEATURES

A TUC2R (WM part #

320) would have 2 control relays on board. (With two different types of optional expansion boards there could be either

OE

A TUC5R (WM part # OE330-21) would have 5 control relays on board. (No expansion possible) (-21 is on metal back plate)
A TUC5R+ (WM part # OE331-21)would have 5 control relays on board. (With a series of different types of expansion boards)

A TUC5RX (WM part # OE332-23) would have 5 control relays on board. (With a series of different types of expansion boards)

A VAVZ-II Box Controller (WM part # OE324-23) is an all in one plastic housing for VAV Zoning control that can be used with the optional
WM OE217 LCD display Temperature sensor. An optional I C Relay expansion board is available for this controller, but it is different

2

than the O 321 and OE322. (-23 is in plastic

E

enclosure)

The most common TUC2R application is what is called VAVBOX control, with a tri-state actuator used to modulate a damper for the temperature
Zone. This VAVBOX software can be configured for pressure dependent operation or pressure independent operation with the addition of an optional
pressure sensor. An optional expansion board can be added for control of Series or Parallel Fan and stages of electric Box Heat. There is another
optional expansion board that can be added instead for control of series or parallel fan, stages of electric box heat, and an analog output for an analog

WM software version is 2.03. WattMaster WCC III VAVBOX. WM Software #

5010. Updated version of WCC II VAVBOX software that

SS

VAVBOX Controllers. Current version is 3.04 and uses the TUC32K2 PAL for use in

The most common TUC5R+ application is what is called a WCC III Heat Pump / CV Air Handler.

WattMaster WCC III Heat Pump / CV Air Handler with CO Sensor control. WM Software # SS5011. The current version is 1.02, and it is for a

²

New to the WCC III is the VAVZ-II Box Controller. SAT 3D version is WM Software # SS5014, and the current software is version 3.10.
When ordering a WattMaster controller, please specify the controller’s "OE" part number followed by the "SS" software part number.
WM part # OE321 is a 4 Relay expansion board for the TUC2R controller and is software dependent. (

5001 only)

SS

WM part # OE322 is a 3 Relay and one analog output for HW valve control, is an expansion board for the TUC2R controller, and is software

There was "custom" TUC2R and TUC5R software that was written in 1980s and 1990s, and you would have to read the EPROM label of the boards
to get replacement controllers if needed. Call WattMaster for further details.
THE SAT 3C/D/F CONTROLLER HAS AN ADDITIONAL FOUR LEDS THAT DISPLAY THE STATUS OF THE RECEIVE AND TRANSMIT

FOR THE SAT LOOP RS-485 AND TUC LOOP RS-485 COMMUNICATIONS. IT DOES THIS FOR BOTH THE SAT III COMMUNICATIONS

LOOP AND THE TUC PORT. IN ADDITION, THERE IS A SEPARATE LOCAL SET LED, AND THREE STATUS LEDS.

THE SAT 2C/D CONTROLLER ONLY HAD AN LED THAT WAS A COMBINATION - POWER, COMMUNICATIONS, AND LOCAL SET

INDICATOR FOR THE SATELLITE MANCHESTER COMMUNICATIONS LOOP.

SAT III - COMMUNICATIONS
THE SAT 3C/D/F CONTROLLER NOW USES RS-485 COMMUNICATIONS. THE SAT 2C/D CONTROLLER USED A TRANSFORMER

COUPLED MANCHESTER ENCODED PROTOCOL THAT WAS DIFFICULT TO TROUBLESHOOT. THE BEST BENEFIT OF HAVING

RS-485 COMMUNICATIONS IS THAT IT CAN BE TROUBLESHOT WITH A DIGITAL VOLTMETER.

SAT 3C/D/F CONTROLLER

"D" MODE

"C" MODE

"C" MODE ADDRESSING NOTES

"C" MODE SAT III ADDRESSING STARTS
AT ADDRESS 8.
EACH "C" MODE SAT III TAKES UP
8 SAT III LOGICAL ADDRESSES.
A "C" MODE SATIII CAN COMMUNICATE
WITH 8 DEVICES TOTAL.

"D" MODE ADDRESSING NOTES

"D" MODE SAT III ADDRESSING STARTS
AT ADDRESS 4.
EACH "D" MODE SAT III TAKES UP 4
SAT III LOGICAL ADDRESSES.
A "D" MODE SAT III CAN COMMUNICATE
WITH 32 DEVICES TOTAL.

SAT IIICD

Communications Interface

TUC XMIT

ON OFF

ON OFF

SAT ADDRESS

1

STATUS

LOCAL SET

16

4

2

8

64

32

128

LOCAL SET DISABLE

OPTION 2

LOCAL SET

OPTION 1

TEST

BATT ON/ OFF

TUC REC

SAT XMIT

SAT REC

D

WATTMASTER CONTROLS
SATELLITE PART NUMBERS

OE421 SAT III CONTROLLER
(SS5003)

OE454 SAT 3C CONTROLLER
(SS5004)

OE455 SAT 3D CONTROLLER
(SS5005)

OE456 SAT 3F CONTROLLER
(SS5016)

3 or 4 more relays)

(-21 is on metal back plate)

Dependent. (SS5010 only)

TUC5R+ board.

was modified from the WattMaster Control’s other line of

older versions of the TUC2R controller so that software upgrades are possible.

(-23 is a Plastic circuit board cover)

controlled actuator for hot water reheat. WattMaster WCC II VAVBOX WM Software #S 5001. Original WCC II VAVBOX - last released 1995. The

S

OPTION 3

OPTION 4

This manual is related to the following products: