Dell PowerEdge FX2/FX2s User Manual
Page 390

The following table describes the show npiv devices brief output shown in
the example below.
Field
Description
ENode-Intf
M I/O Aggregator and MXL 10/40GbE Switch with the FC
Flex IO module Ethernet interface (slot/port) to which a
server CNA is connected.
ENode-WWPN
Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan
VLAN ID of the dedicated VLAN used to transmit FCoE traffic
to and from the fabric.
Fabric-Intf
Fabric-facing Fibre Channel port (slot/port) on which FC
traffic is transmitted to the specified fabric.
Fabric-Map
Name of the FCoE map containing the FCoE/FC
configuration parameters for the server CNA-fabric
connection.
LoginMethod
Method used by the server CNA to log in to the fabric; for
example:
FLOGI - ENode logged in using a fabric login (FLOGI).
FDISC - ENode logged in using a fabric discovery (FDISC).
Status
Operational status of the link between a server CNA port
and a SAN fabric: Logged In - Server has logged in to the
fabric and is able to transmit FCoE traffic.
Example
Dell# show npiv devices brief
Total NPIV Devices = 2
---------------------------------------------------------------
----------------------------
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf
Fabric-Map LoginMethod Status
---------------------------------------------------------------
---------------------------
Te 0/12 20:01:00:10:18:f1:94:20 1003 Fc 0/5
fid_1003 FLOGI LOGGED_IN
Te 0/13 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/0
fid_1003 FDISC LOGGED_IN
Usage
Information
The following table describes the show npiv devices output shown in the
example below.
Field
Description
ENode [number]
A server CNA that has successfully logged in to a fabric over
an M I/O Aggregator and MXL 10/40GbE Switch with the FC
Flex IO module Ethernet port in ENode mode.
390