Default settings, Other auto-configured settings, Stacking mode – Dell PowerEdge FX2/FX2s User Manual
Page 20

Dell(conf)#stack-unit 0 iom-mode programmable-mux
Select this mode to configure PMUX mode CLI commands.
For more information on the PMUX mode, refer to
PMUX Mode of the IO Aggregator
.
Stacking mode
stack-unit unit iom-mode stack
CONFIGURATION mode
Dell(conf)#stack-unit 0 iom-mode stack
Select this mode to configure Stacking mode CLI commands.
For more information on the Stacking mode, refer to
Default Settings
The I/O Aggregator provides zero-touch configuration with the following default configuration settings:
• Default user name (root)
• Password (calvin)
• VLAN (vlan1) and IP address for in-band management (DHCP-assigned)
• IP address for out-of-band (OOB) management (DHCP-assigned)
• Read-only SNMP community name (public)
• Broadcast storm control (enabled)
• Unregistered Multicast Packets flooding (enabled)
• IGMP snooping in all VLANs except the default VLAN (enabled)
• VLAN configuration (all ports belong to all VLANs)
You can change any of these default settings using the CLI. Refer to the appropriate chapter for details.
NOTE: You can also change many of the default settings using the chassis management controller
(CMC) interface. For information about how to access the CMC to configure an Aggregator, refer to
the Dell Chassis Management Controller (CMC) User’s Guide on the Dell Support website at http://
support.dell.com/support/edocs/systems/pem/en/index.htm.
Other Auto-Configured Settings
After the Aggregator powers on, it auto-configures and is operational with software features enabled,
including:
• VLANs: All ports are configured as members of all (4094) VLANs. All VLANs are up and can send or
receive layer 2 traffic. For more information, refer to
.
• Data Center Bridging Capability Exchange Protocol (DCBX)
20