Npiv proxy gateway, Show fcoe-map, 29 npiv proxy gateway – Dell PowerEdge FX2/FX2s User Manual
Page 288

29
NPIV Proxy Gateway
The N-port identifier virtualization (NPIV) Proxy Gateway (NPG) feature provides FCoE-FC bridging
capability on the FN I/O Aggregator with the FC Flex IO module switch, allowing server CNAs to
communicate with SAN fabrics over the FN I/O Aggregator with the FC Flex IO module.
To configure the FN I/O Aggregator with the FC Flex IO module to operate as an NPIV proxy gateway,
use the following commands:
show fcoe-map
Display the Fibre Channel and FCoE configuration parameters in FCoE maps.
Syntax
show fcoe-map [brief | map-name]
Parameters
brief
Displays an overview of currently configured FCoE maps.
map-name
Displays the FC and FCoE configuration parameters in a
specified FCoE map. The FCoE map is applied on Ethernet
(FCoE) and FC ports to transmit FC storage traffic to a
specified fabric.
Command
Modes
• EXEC
• EXEC Privilege
Command
History
Version 9.6(0.0)
Supported on the FN2210S Aggregator.
Version 9.3(0.0)
Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
Usage
Information
Use the show fcoe-map command to display the FC and FCoE parameters used
to configure server-facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE
maps on an FN 2210S Aggregator with the FC Flex IO module NPIV proxy gateway.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN
fabric to which FC storage traffic is sent, and the FCoE VLAN to be used must be
unique.
288