Fcoe-map – Dell PowerEdge FX2/FX2s User Manual
Page 383

Parameters
fc-map-value
Enter the unique MAC address prefix used by a SAN fabric.
The range of FC-MAP values is from 0EFC00 to 0EFCFF.
Defaults
None
Command
Modes
FCoE MAP
Command
History
Version 9.6(0.0)
Supported on the FN 2210S Aggregator.
Version 9.3(0.0)
Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.
Usage
Information
The FC-MAP value you enter must match the FC-MAP value used by an FC switch
or FCoE forwarder (FCF) in the fabric. An FCF switch accepts only FCoE traffic that
uses the correct FC-MAP value.
The FC-MAP value is used to generate the fabric-provided MAC address (FP-MAC).
The FPMA is used by servers to transmit FCoE traffic to the fabric. An FC-MAP can
be associated with only one FCoE VLAN and vice versa.
In an FCoE map, the FC-MAP value, fabric ID, and FCoE VLAN parameters must be
unique.
To remove a configured FC-MAP value from an FCoE map, enter the no fc-map
command.
Related
Commands
— creates an FCoE map which contains the parameters used in the
communication between servers and a SAN fabric.
— displays the Fibre Channel and FCoE configuration parameters in
FCoE maps.
fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs
and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.
Syntax
fcoe-map map-name
Parameters
map-name
Maximum: 32 alphanumeric characters.
Defaults
On the FN2210S Aggregator with PMUX modules, the following parameters are
applied on all the PMUX module interfaces:
• Description: SAN_FABRIC
• Fabric-id: 1002
• Fcoe-vlan: 1002
383