Offline stack-unit, Show diag – Dell PowerEdge FX2/FX2s User Manual
Page 273

Command
History
Version 9.4(0.0)
Supported on the FN I/O aggregator.
offline stack-unit
Place a stack unit in the offline state.
Syntax
offline stack-unit number
Parameters
number
Enter the stack-unit number. The range is from 0 to 5.
Defaults
none
Command
Modes
EXEC Privilege
Command
History
Version 9.4(0.0)
Supported on the FN I/O aggregator.
Usage
Information
While executing the offline stack unit CLI, the following warning message is
displayed:
Dell#offline stack-unit 0
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running
Diagnostics.
Please make sure that stacking/fanout not configured for
Diagnostics execution.
Also reboot/online command is necessary for normal operation
after the offline command is issued.
Proceed with Offline [confirm yes/no]:no
Dell#
Make sure that stacking is not configured for Diagnostics execution. Also, reboot/
online command is necessary for normal operation after the offline command is
issued.
show diag
View diagnostics information.
Syntax
show diag {information | stack-unit unit-id [detail | summary]
| testcase}
Parameters
information
Enter the keyword information to view current diagnostics
information in the system.
273