1 technical data, Technical data, General data/operating conditions – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 64: Parameter setting, With communication module lecom−a (rs232)

background image

Parameter setting

With communication module LECOM−A (RS232)

6−9

L

EDB82MV752 EN 5.2

6.3

Parameter setting using the LECOM−A (RS232) communication
module

The LECOM−A (RS232) communication module connects the controller to a host (e.g. PC) via the
RS232 interface.

You need the following accessory components to use the communication module:

·

Parameterisation software Global Drive Control easy (GDC easy)"

·

PC system cable

·

Connecting cable

6.3.1

Technical data

6.3.1.1

General data/operating conditions

Communication module type

E82ZBL

Communication medium

RS232 (LECOM−A)

Communication protocol

LECOM−A/B V2.0

Character format

7E1: 7 bits ASCII, 1 stop bit, 1 start bit, 1 parity bit (even)

Baud rate [Bit/s]

1200, 2400, 4800, 9600, 19200

LECOM−A node

Slave

Network topology

Point−to−point

Max. number of nodes

1

Max. cable length

15 m

Communication time

See table

PC connection

9−pole Sub−D socket

DC voltage supply

Internal

Insulation voltage to reference
earth/PE

50 V AC

Type of protection

EN60529

IP20

outside the wire range of the terminals
on the motor side

NEMA 250

Protection against accidental contact to
type 1

Climatic conditions

Permissible
Temperature ranges

Storage

IEC/EN 60721−3−1

1K3 (−25 °C...+60 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 °C...+70 °C)

Operation

IEC/EN 60721−3−3

3K3 (0 °C...+55 °C)

Dimensions (L x B x H)

75 mm x 62 mm x 23 mm