Function library

Free connection of digital signals, message output

7−79

L

EDB82MV752 EN 5.2

Selection under C0415/x

Relays/digital output (not inverted)

32

Digital input X3/E1

Picks up/HIGH, if HIGH level is applied to the
corresponding digital input

33

Digital input X3/E2

34

Digital input X3/E3

35

Digital input X3/E4

36 (A)

Digital input X3/E5

37 (A)

Digital input X3/E6

38

PTC input X2.2/T1, X2.2/T2

Picks up/HIGH, if the potential−free switch is connected
to X2.2/T1, X2.2/T2

40 ... 55

AIF control word (AIF−CTRL) Bit 0 ... Bit 15

Picks up/HIGH, if the corresponding bit is set

60 ... 75

CAN−IN1.W1 or FIF−IN.W1 bit 0 ... bit 15

80 ... 95

CAN−IN1.W2 or FIF−IN.W2 bit 0 ... bit 15

100 ... 115

CAN−IN2.W1 bit 0 ... bit 15

120 ... 135

CAN−IN2.W2 bit 0 ... bit 15

140

Torque threshold 1 reached (MSET1=MOUT)

Picks up/HIGH, if the condition is met

141

Torque threshold 2 reached (MSET2=MOUT)

142

Process controller output limit reached (PCTRL1−LIM)

7.11.3

Free configuration of digital process data output words

Description

·

The digital process data output words can be freely assigned to internal digital signals. With
this you can summarise status information which will be automatically assigned to status word
bits:

– The configuration under C0417 is mapped to the AIF status word 1 (C0150), FIF output word

1 (FIF−OUT.W1) and output word 1 of the CAN object 1 (CAN−OUT1.W1).

– The configuration under C0418 is mapped to the AIF status word 2 (C0151), FIF output word

2 (FIF−OUT.W2) and output word 1 of the CAN object 2 (CAN−OUT2.W1).

·

A signal source can be assigned to several targets.