beautypg.com

Terminal assignment − application i/o e82zafac001, Installation, Electrical installation − connections – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 37

background image

Installation

Electrical installation − Connections

4−12

L

EDB82MV752 EN 5.2

4.2.4.3

Terminal assignment − application I/O E82ZAFAC001

Stop !

Control cables must always be shielded to prevent interference injections!

Electrical connection

Terminal strip with screw connection

Possible connections

rigid: 1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.0 mm

2

(AWG 18)

with wire end ferrule, without plastic sleeve
0.5 mm

2

(AWG 20)

with wire end ferrule, with plastic sleeve
0.5 mm

2

(AWG 20)

Tightening torque

0.22 ... 0.25 Nm (1.9 ... 2.2 lb−in)

Bare end

5 mm