Appendix, Code table – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 227
Appendix
Code table
14−26
L
EDB82MV752 EN 5.2
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0185*
Switching window
for "Frequency
setpoint reached
(C0415/x = 4)" and
"NSET1−RFG1−I=O
(C0415/x = 5)"
0
0
{1 %}
80
·
C0415/x = 4 and C0415/x = 5 are
active within a window around
NSET1−RFG1−IN
·
Window in C0185 = 0%:
± 0,5 % ref. to C0011
·
Window in C0185 > 0%:
± C0185 ref. to NSET1−RFG1−IN
C0189*
(A)
Output signal
compensator
(PCTRL1−FOLL1−OU
T)
−650.00
{0.02 Hz}
650.00 Only display
Compensator = PCTRL1−FOLL1
C0190*
v
(A)
Main and additional
setpoint
(PCTRL1−ARITH1)
1
0
X + 0
Mathematical addition of mains setpoint
(NSET1−NOUT) and additional setpoint
(PCTRL1−NADD)
The result is in Hz
X = NSET1−NOUT
Y = PCTRL1−NADD
1
X + Y
2
X − Y
3
X
@ Y
C0011
4
X
Y
@ C0011
100
5
X
@ C0011
C0011
* Y
C0191
(A)
Compensator
acceleration time
5.00
0.00
{0.02 s}
1300.00 Ref. to change 0 Hz ... C0011
C0192
(A)
Compensator
deceleration time
5.00
0.00
{0.02 s}
1300.00 Ref. to change C0011 ... 0 Hz
C0193
(A)
Compensator reset
5.00
0.00
{0.02 s}
1300.00 Ref. to change C0011 ... 0 Hz
Decelerate compensator to "0"
C0194
(A)
Min. compensator
activation threshold
−200.00 −200.00
{0.01 %}
200.00 Ref. to C0011
If the value falls below C0194:
Compensator "runs" at C0191 or C0192
direction −C0011
C0195
(A)
Max. compensator
activation threshold
200.00 −200.00
{0.01 %}
200.00 Ref. to C0011
If C0195 is exceeded:
Compensator "runs" at C0191 or C0192
direction +C0011
C0196*
v
Activation of
auto–DCB
0
0
Auto−DCB active, if PCTRL1−SET3 < C0019
^ 7−30
1
Auto−DCB active, if PCTRL1−SET3 < C0019 and
NSET1−RFG1−IN < C0019
C0200*
Software ID
Read only on PC
x = main version, y = subversion
82S8212V_xy000
8200 vector 0.25 ... 11 kW
82S8212V_xy010
8200 vector 15 ... 90 kW
C0201*
Software creation
date
Read only on PC
C0202*
Software ID
Output in keypad as string in four parts at four characters
each
Read only in keypad
1
82S8
2
212 V
3
_xy0
x = main version, y = subversion
4
zz
00 = 8200 vector 0.25 ... 11 kW
10 = 8200 vector 15 ... 90 kW
C0220*
Acceleration time −
additional setpoint
(PCTRL1−NADD)
5.00
0.00
{0.02 s}
1300.00 Main setpoint
ð C0012
^ 7−24
C0221*
Deceleration time −
additional setpoint
(PCTRL1−NADD)
5.00
0.00
{0.02 s}
1300.00 Main setpoint
ð C0013