beautypg.com

Function library, Free connection of analog signals – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 134

background image

Function library

Free connection of analog signals

7−63

L

EDB82MV752 EN 5.2

Output signal at selection 8

When using no process controller the output signal at selection 8 is proportional to the output
frequency without slip compensation.
Application example for selection 6

The output signal is reciprocal to the output frequency. This signal can be used for the time indication
(e.g. machining time of a product).

Example: Output signal = 0 ... 10 V

U

out

[V]

+ 1.00 V @ C0011

f

@ C0420

128

V

out

Output signal

f

Output frequency

C0011

Maximum output frequency

C0420

Gain of analog output

6.00

5.00

4.00

3.00

2.00

1.00

0.00

0

10

20

30

40

50

60

Uout

[V]

f [Hz]

C0420 = 128

8200vec536

Fig. 7−15

Output signal of the function "1/output frequency"