beautypg.com

Parameter setting, With keypad – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 58

background image

Parameter setting

With keypad

6−3

L

EDB82MV752 EN 5.2

0

Function keys

Key

Function

Explanation

u

Enable drive controller

X3/28 must be set to HIGH level.

s

Inhibit drive controller (CINH) or quick stop (QSP)

Configuration in C0469.

t

Change function bar 1

« function bar 2

xw

To the right/left in the active function bar.

The current function is framed.

zy

Increase/decrease value.
change quickly: keep key pressed

Only blinking values can be changed.

v

Save parameters if

p

is blinking.

confirmation by

STOre

in the display.

1

Status displays
Description of the fault messages: (

^ 8−1 ff)

Display

Meaning

Explanation

d

Ready for operation

c

Pulse inhibit

Power outputs inhibited

b

Set current limit is exceeded

C0022 (in motor mode) or C0023 (in generator mode)

e

Warning active

a

Error active

2

Bar graph display

Set value in C0004 in %.
(Lenze setting: device utilisation C0056).

Display range: − 180 % ... + 180 % (every scale line = 20 %)

3

Function bar 1

Function

Meaning

Explanation

j

Setpoint selection via

yz

Not possible with active password protection (display =

"loc"

)

g

Display function:

·

User menu, memory location 1 (C0517/1), display

·

Display active parameter set

Active after every mains connection

f

Select codes

Active code number shown on four−digit display

6

k

Select subcodes

Active subcode number shown on three−digit display

7

i

Change parameter value of a (sub−) code

Current value shown on five−digit display

8

h

Display values with more than 5 digits

H:

high−order digits

"HI"

shown on display

L:

low−order digits

"lo"

shown on display

4

Function bar 2

Function

Meaning

Explanation

m

Select parameter set 1 ... parameter set 4 for changing

·

Display e. g. PS

2

(

5

)

·

Activating parameter sets can be effected via digital signals only
(configuration with C0410).

n

Select node on system bus (CAN)

The node selected can be parameterised from the current drive.

r

= function active

o

Select menu
The user menu is active after every mains switching. If required,
change to

all

.

user

List of the codes in the user menu (C0517)

all

List of all codes

funci

Only specific codes for bus function modules, e.g. INTERBUS,

PROFIBUS−DP and LECOM-B