Parameter setting, With keypad – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 58
Parameter setting
With keypad
6−3
L
EDB82MV752 EN 5.2
0
Function keys
Key
Function
Explanation
u
Enable drive controller
X3/28 must be set to HIGH level.
s
Inhibit drive controller (CINH) or quick stop (QSP)
Configuration in C0469.
t
Change function bar 1
« function bar 2
xw
To the right/left in the active function bar.
The current function is framed.
zy
Increase/decrease value.
change quickly: keep key pressed
Only blinking values can be changed.
v
Save parameters if
p
is blinking.
confirmation by
STOre
in the display.
1
Status displays
Description of the fault messages: (
^ 8−1 ff)
Display
Meaning
Explanation
d
Ready for operation
c
Pulse inhibit
Power outputs inhibited
b
Set current limit is exceeded
C0022 (in motor mode) or C0023 (in generator mode)
e
Warning active
a
Error active
2
Bar graph display
Set value in C0004 in %.
(Lenze setting: device utilisation C0056).
Display range: − 180 % ... + 180 % (every scale line = 20 %)
3
Function bar 1
Function
Meaning
Explanation
j
Setpoint selection via
yz
Not possible with active password protection (display =
"loc"
)
g
Display function:
·
User menu, memory location 1 (C0517/1), display
·
Display active parameter set
Active after every mains connection
f
Select codes
Active code number shown on four−digit display
6
k
Select subcodes
Active subcode number shown on three−digit display
7
i
Change parameter value of a (sub−) code
Current value shown on five−digit display
8
h
Display values with more than 5 digits
H:
high−order digits
"HI"
shown on display
L:
low−order digits
"lo"
shown on display
4
Function bar 2
Function
Meaning
Explanation
m
Select parameter set 1 ... parameter set 4 for changing
·
Display e. g. PS
2
(
5
)
·
Activating parameter sets can be effected via digital signals only
(configuration with C0410).
n
Select node on system bus (CAN)
The node selected can be parameterised from the current drive.
r
= function active
o
Select menu
The user menu is active after every mains switching. If required,
change to
all
.
user
List of the codes in the user menu (C0517)
all
List of all codes
funci
Only specific codes for bus function modules, e.g. INTERBUS,
PROFIBUS−DP and LECOM-B