beautypg.com

Function library, Setting of v, Motor with forced ventilation: i – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 78: 0,8 i

background image

Function library

Selection of control mode, optimisation of operating behaviour

7−7

L

EDB82MV752 EN 5.2

Setting of V

min

boost

Load−independent boost of the motor voltage for output frequencies below the V/f rated frequency.
This serves to optimise the torque behaviour.

C0016 must always be adapted to the asynchronous motor used. Otherwise, the motor might be
destroyed by overtemperature or the controller might be driven with overcurrent:

1. Operate the motor in idle running at slip frequency (f

» 5 Hz):

f

s

+ f

r

@

n

rsyn

* n

r

n

rsyn

n

rsyn

+

f

r

@ 60

p

f

s

Slip frequency [Hz]

f

r

Rated motor frequency according to nameplate [Hz]

r

rsyn

Synchronous motor speed [min

−1

]

r

r

Rated motor speed according to nameplate [min

−1

]

p

Number of pole pairs

2. V

min

until the following motor current is reached:

A Motor in short−term operation at 0 Hz

£ f £ 25 Hz:

– Motor with integrated ventilation: I

motor

£

I

r motor

– Motor with forced ventilation: I

motor

£

I

r motor

B Motor in continuous operation at 0 Hz

£ f £ 25 Hz:

– Motor with integrated ventilation: I

motor

£ 0,8 I

r motor

– Motor with forced ventilation: I

Motor

£ I

r motor

)

Note!

For adjustment, observe the thermal performance of the connected asynchronous
motor at low output frequencies:

l

As experience shows it is possible to operate standard asynchronous motors
with insulation class B for a short time with rated current 0 Hz

£ f £ 25 Hz.

l

Contact the motor manufacturer for exact setting values for the max. permissible
motor current in the lower frequency range of self−ventilated motors.

C0015

C0016

C0015

2

C0016

2

V [V]

out

f [Hz]

V

(100 %)

rmot

1/N/PE AC 264 V

3/PE AC 264 V

3/PE AC 550 V

1/N/PE AC 180 V

3/PE AC 100 V

3/PE AC 320 V

C0015

C0016

V [V]

out

f [Hz]

V

(100 %)

rmot

1/N/PE AC 264 V

3/PE AC 264 V

3/PE AC 550 V

1/N/PE AC 180 V

3/PE AC 100 V

3/PE AC 320 V

8200vec537

8200vec538

Fig. 7−3

Umin boost at linear and square−law V/f characteristic