Appendix
Code table
14−37
L
EDB82MV752 EN 5.2
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0411
v
Level inversion of
digital inputs
0
0
Level inversion is switched off
·
By entering the sum of the selected
values you can invert several inputs
·
C0114 and C0411 are identical
·
The function "Parameter set
changeover" cannot be inverted!
1
E1 inverted
2
E2 inverted
4
E3 inverted
8
E4 inverted
16
E5 inverted
only application I/O
32
E6 inverted
only application I/O
64
T1/T2 inverted
T1/T2 can only be connected to
potential−free switches.
T1/T2 is active, if the switch is open.
C0412
v
Free configuration
of analog input
signals
Link between analog signal sources and internal analog
signals
A selection under C0005 or C0007 will
be copied to the corresponding subcode
of C0412. A change of C0412 sets C0005
= 255, C0007 = 255!
^ 7−57
1 Setpoint 1
(NSET1–N1)
1
Analog input 1 (AIN1−OUT):
X3/8 (Standard−I/O)
X3/1U or X3/1I (Application−I/O)
Either NSET1−N1 or
NSET1−N2 active
Changeover with C0410/17
Parameter
channel:
C0046
2 Setpoint 2
(NSET1−N2)
1
Parameter
channel:
C0044
3 Additional setpoint
(PCTRL1−NADD)
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module
Is added to NSET1−N1,
NSET1−N2, JOG values and
the function
j
of the
keypad
Parameter
channel:
C0049
4 Process controller
setpoint 1
(PCTRL1−SET1)
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module
5 Act. process
controller value
(PCTRL1−ACT)
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module
Parameter
channel:
C0051, if
C0238 = 1, 2
6 Torque setpoint or
torque limit value
(MCTRL1−MSET)
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module
·
Observe C0014!
·
Actual torque values
not required.
·
16384
º 100 % torque
setpoint
·
Condition for selection
via terminal (C0412/6 =
1, 2 or 4):
– The gain of the
analog input is set
to: C0414/x, C0426
= 32768/C0011 [%]
Parameter
channel:
C0047
7 Reserved
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module
8 MCTRL1−VOLT−ADD
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module
Only for special applications. Modifications
only when agreed on by Lenze!
9 MCTRL1−PHI−ADD
255
Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module