Appendix, Code table – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 238

background image

Appendix

Code table

14−37

L

EDB82MV752 EN 5.2

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0411

v

Level inversion of
digital inputs

0

0

Level inversion is switched off

·

By entering the sum of the selected
values you can invert several inputs

·

C0114 and C0411 are identical

·

The function "Parameter set
changeover" cannot be inverted!

1

E1 inverted

2

E2 inverted

4

E3 inverted

8

E4 inverted

16

E5 inverted

only application I/O

32

E6 inverted

only application I/O

64

T1/T2 inverted

T1/T2 can only be connected to
potential−free switches.
T1/T2 is active, if the switch is open.

C0412

v

Free configuration
of analog input
signals

Link between analog signal sources and internal analog
signals

A selection under C0005 or C0007 will
be copied to the corresponding subcode
of C0412. A change of C0412 sets C0005
= 255, C0007 = 255!

^ 7−57

1 Setpoint 1

(NSET1–N1)

1

Analog input 1 (AIN1−OUT):
X3/8 (Standard−I/O)
X3/1U or X3/1I (Application−I/O)

Either NSET1−N1 or
NSET1−N2 active
Changeover with C0410/17

Parameter
channel:
C0046

2 Setpoint 2

(NSET1−N2)

1

Parameter
channel:
C0044

3 Additional setpoint

(PCTRL1−NADD)

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

Is added to NSET1−N1,
NSET1−N2, JOG values and
the function

j

of the

keypad

Parameter
channel:
C0049

4 Process controller

setpoint 1
(PCTRL1−SET1)

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

5 Act. process

controller value
(PCTRL1−ACT)

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

Parameter
channel:
C0051, if
C0238 = 1, 2

6 Torque setpoint or

torque limit value
(MCTRL1−MSET)

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

·

Observe C0014!

·

Actual torque values
not required.

·

16384

º 100 % torque

setpoint

·

Condition for selection
via terminal (C0412/6 =
1, 2 or 4):

– The gain of the

analog input is set
to: C0414/x, C0426
= 32768/C0011 [%]

Parameter
channel:
C0047

7 Reserved

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

8 MCTRL1−VOLT−ADD

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

Only for special applications. Modifications
only when agreed on by Lenze!

9 MCTRL1−PHI−ADD

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module