Important notes

7−1

L

EDB82MV752 EN 5.2

7

Function library

The function library gives all information needed to adapt your controller to your application. The
chapter is subdivided into the following sections:

·

Select control mode, optimise operating behaviour

·

Limit value setting

·

Acceleration, decleration, braking, stopping

·

Configuration of analog and digital setpoints

·

Motor data entry/automatic detection

·

Process controller I

max

controller

·

Free connection of analog signals

·

Free connection of digital signals, message output

·

Thermal motor monitoring , error detection

·

Display of operating data, diagnostics

·

Parameter set management

·

Individual grouping of drive parameters − The user menu

Tip!

·

Signal flow charts show how codes are integrated into signal processing.

(

^ 14−1 ff.)

·

The code table lists all codes in numerical order and explains them briefly.

(

^ 14−10 ff.)

For free signal configuration:

·

Select the source from the targets point of view:

– Ask yourself Where does the signal come from?"
– That makes it easy to find the correct entry for a code.

·

A source can have several targets:
– It is thus possible that double assignments occur when targets are assigned to sources.

– For instance, the assignment of E1 remains the same even if the frequency input E1 is

activated (Lenze setting: "JOG1 activation!). The previous assignment must be deleted with
C0410/1 = 255 to ensure trouble−free operation.

– Ensure that only the targets wanted are assigned to a source.

·

A target can have one source only.