beautypg.com

3 digital setpoints via frequency input, Digital setpoints via frequency input, Function library – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 110

background image

Function library

Configuration of analog and digital setpoints and actual values

7−39

L

EDB82MV752 EN 5.2

7.6.3

Digital setpoints via frequency input

Description

It is possible to configure the digital inputs E1 and E2 of the standard I/O or application I/O as
frequency input. This enables you to select a digital frequency as setpoint or actual value:

·

For operation with standard I/O

– single−tracked: 0 ... 10 kHz at X3/E1
– two−tracked: 0 ... 1 kHz at X3/E1 and X3/E2

·

For operation with application I/O
– single−tracked: 0 ... 100 kHz at X3/E1

– two−tracked: 0 ...100 kHz at X3/E1 and X3/E2

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze

Selection

C0425*

v

Configuration
frequency input
single track X3/E1
(DFIN1)

2

f

r

Df

min

t

f

max

·

f

r

= Normalisation frequency

– f

r

corresponds to C0011

·

Df

min

= Resolution

·

t = Scanning rate

– The lower the scanning rate the

higher the dynamic response.

·

f

max

= Maximum frequency which can

be processed independently of C0425

– Set C0425 that the frequency coming

from the encoder is lower than f

max

·

Activate frequency input with
C0410/24 = 1

·

Adjust frequency input under C0426 and
C0427

^ 7−39

0

100 Hz

1/200

1 s

300 Hz

1

1 kHz

1/200

100 msec

3 kHz

2

10 kHz

1/200

10 msec

10 kHz

3

10 kHz

1/1000

50 msec

10 kHz

4

10 kHz

1/10000

500 ms

10 kHz

5 (A)

102.4 kHz

1/400

2 msec

102.4 kHz

6 (A)

102.4 kHz

1/1000

5 msec

102.4 kHz

7 (A)

102.4 kHz

1/2000

10 msec

102.4 kHz

Configuration
frequency input two
tracks X3/E1, X3/E2
(DFIN1)

10

100 Hz

1/200

1 s

300 Hz

11

1 kHz

1/200

100 msec

3 kHz

12 (A)

10 kHz

1/200

10 msec

10 kHz

13 (A)

10 kHz

1/1000

50 msec

10 kHz

14 (A)

10 kHz

1/10000

500 ms

10 kHz

15 (A)

102.4 kHz

1/400

2 msec

102.4 kHz

16 (A)

102.4 kHz

1/1000

5 msec

102.4 kHz

17 (A)

102.4 kHz

1/2000

10 msec

102.4 kHz

C0426*

Gain frequency
input X3/E1, X3/E2
(A) (DFIN1−GAIN)

100

−1500.0

{0.1 %}

1500.0

C0426

+

f

N

@ p

z

@ C0011 @

100 %

·

f

r

= Normalisation frequency from

C0425

·

p = Number of pole pairs of the motor

·

z = Number of increments per revolution
of the encoder

·

C0011 = Maximum output frequency
(corresponds to maximum process
speed of the motor)

C0427*

Offset frequency
input X3/E1, X3/E2
(A) (DFIN1−OFFSET)

0.0

−100.0

{0.1 %}

100.0