Function library

Free connection of digital signals, message output

7−68

L

EDB82MV752 EN 5.2

7.11

Free interconnection of digital signals

7.11.1

Free configuration of digital input signals

Description

·

Internal digital signals can be freely assigned to external digital signal sources. It is thus
possible to achieve a freely configured control of the controller

– Digital inputs X3/E1 ... X3/E6
– Digital process data input words

·

A signal source can be assigned to several targets. Please ensure reasonable assignments.
Otherwise it is possible to activate functions which cannot be operated together (e.g. a digital
signal linked with quick stop and DC braking at the same time).

)

Note!

Use C0007 to configure some internal digital signals with the digital inputs X3/E1 ...
X3/E4 block by block. The corresponding subcodes of C0410 will be adapted
automatically.