Appendix, Code table – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 239

background image

Appendix

Code table

14−38

L

EDB82MV752 EN 5.2

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0412

v

(cont.)

Analog signal source possible for C0412

^ 7−57

0

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

1

Analog input 1 (AIN1−OUT)
X3/8 (Standard−I/O)
X3/1U or X3/1I (Application−I/O)

2

Frequency input (DFIN1−OUT)

Observe C0410/24, C0425, C0426, C0427

3

Motor potentiometer (MPOT1−OUT)

4 (A)

Analog input 2 (AIN2−OUT)
X3/2U or X3/2I

5 ... 9

Input signal is constantly 0 (FIXED0)

10

AIF input word 1 (AIF−IN.W1)

Only evaluated if C0001 = 3!

11

AIF input word 2 (AIF−IN.W2)

20

CAN−IN1.W1 or FIF−IN.W1

± 24000

º ±480 Hz

2

14

º 100 % rated motor torque

21

CAN−IN1.W2 or FIF−IN.W2

22

CAN−IN1.W3 or FIF−IN.W3

23

CAN−IN1.W4 or FIF−IN.W4

30

CAN−IN2.W1

31

CAN−IN2.W2

32

CAN−IN2.W3

33

CAN−IN2.W4

200

Signals are assigned word by word from fieldbus
function module to FIF (e.g. INTERBUS or
PROFIBUS−DP)

See C0005

228 (A)

PCTRL1−ACT

229 (A)

PCTRL1−SET

230 (A)

PCTRL1−OUT

231 (A)

NSET1−RFG1−IN

232 (A)

NSET1−NOUT

233 (A)

PCTRL1−PID−OUT

234 (A)

PCTRL1−NOUT

255

Not assigned (FIXED−FREE) or selected via keypad
or parameter channel of an AIF bus module

Either NSET1−N1 or NSET1−N2 active

C0413* Offset − analog

inputs

−200.0

{0.1 %}

200.0 The upper limit of the setpoint range from

C0034 corresponds to 100 %

^ 7−34

1 AIN1−OFFSET

0.0

Setting for X3/8 or X3/1U, X3/1I
C0413/1 and C0026 are the same

2 AIN2−OFFSET

0.0

Setting for X3/2U, X3/2I
(only application I/O)

C0414* Gain − analog

inputs

−1500.0

{0.1 %}

1500.0

·

100.0 % = gain 1

·

Inverted setpoint selection through
negative gain and negative offset

1 AIN1−GAIN

100.0

Setting for X3/8 or X3/1U, X3/1I
C0414/1 and C0027 are the same

2 AIN2−GAIN

100.0

Setting for X3/2U, X3/2I
(only application I/O)