Function library

Process controller, current limitation controller

7−52

L

EDB82MV752 EN 5.2

Function

1. The dancer deflects to the bottom. The dancer control (V

T

) decreases.

2. V2 increases.

M

3~

8200

3

E

A

U

T

+10 V

0 V ... 10 V

~ V1

V1

V2

S

8200vec534

Fig. 7−13

Example: Dancer control with adding influence of the process controller

Example of subtractive influence

The effective direction of the process controller output to the main setpoint is subtractive.
Settings

·

C0051 = Positive actual value

·

C0181 = select positive setpoint

·

C0238 = 1 (with frequency feedforward control)

·

Potentiometer terminals of the dancer

– End (E) = +10 V

– Start (A) = GND

Function

1. The dancer deflects to the bottom. The dancer control (V

T

) increases.

2. V1 decreases.

M

3~

8200

3

A

E

S

+10 V

0 V ... 10 V

~ V2

V2

V1

U

T

8200vec535

Fig. 7−14

Example: Dancer control with subtractive influence of the process controller