Installation, Electrical installation − connections – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 36
Installation
Electrical installation − Connections
4−11
L
EDB82MV752 EN 5.2
X3/
−4−
Signal type
Function
Level
Lenze setting: Bold print
62
Analog output
Output frequency
0 ... + 6 V
0 ... + 10 V
1)
7
−
GND1, reference potential for analog signals
−
8
Analog input
Act. or setpoint input
Change range using the DIP switch and C0034
·
Master voltage
0 ... +5 V
0 ... +10 V
−10 V ... +10 V
2)
·
Master current
0 ... +20 mA
+4 ... +20 mA
+4 ... +20 mA (open−circuit monitored)
9
−
Internal, stabilised DC voltage supply for setpoint potentiometer
+5.2 V
20
−
Internal DC voltage supply for control of digital inputs and outputs
+20 V
± 10 % (ref.: X3/7)
28
Digital inputs
Controller inhibit (CINH)
1 = START
E1
3)
Activation of JOG frequencies
JOG1 = 20 Hz
JOG2 = 30 Hz
JOG3 = 40 Hz
E1
E2
JOG1
1
0
E2
3)
JOG2
0
1
JOG3
1
1
E3
DC−injection brake (DCB)
1 = DCB
E4
Change of direction of rotation
CW/CCW rotation
E4
CW
0
CCW
1
39
−
GND2, reference potential for digital signals
−
A1
Digital output
Ready for operation with
– internal supply:
– external supply:
0 ... +20 V
0 ... +24 V
59
−
DC supply for X3/A1
– internal (bridge to X3/20):
– external:
+20 V
+24 V
1)
Output level 0 ... + 10 V: Adapt offset (C0109/C0422) and gain (C0108/C0420)
2)
Adjust offset (C0026) and gain (C0027) separately for each function module:
After replacing the function module or the basic device
After loading the Lenze setting
3)
Alternatively frequency input 0 ... 10 kHz single−tracked or 0 ...1 kHz double−tracked, configuration via C0425