Appendix

Code table

14−33

L

EDB82MV752 EN 5.2

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0358*

v

Reset node

0

0

Without function

·

Only for the E82ZAFCC system bus
function module on the FIF interface.

·

System bus reset node set−up

1

System bus reset

C0359*

v

System bus status

0

Operational

·

Only for the E82ZAFCC system bus
function module on the FIF interface.

·

Only display

1

Pre−operational

2

Warning

3

Bus off

C0360*

v

Control of process
data channel CAN1

1

0

Event or time control

Only for the E82ZAFCC system bus function
module on the FIF interface.

1

Sync control

C0370*

v

Activate remote
parameter setting
via system bus
(CAN)

0

Deactivated

·

Only for the E82ZAFCC system bus
function module on the FIF interface.

·

Can only be read when using all other
bus function modules on FIF.

1 ... 63

Activates corresponding CAN address

1 = CAN address 1
63 = CAN address 63

255

No system bus (CAN)

Only display

C0372*

Function module
identification

0

No function module

Only display

1

Standard I/O or AS−i

2

System bus (CAN)

6

Other function module on FIF
e.g. application I/O, INTERBUS, ...

10

No valid recognition

C0395*

LONGWORD
process input data

Bit 0..15

Controller word (mapping to C0135)

For bus operation only

·

Sending of control word and main
setpoint in a telegram to controller

·

In keypad: display only (hexadecimal)

Bit 16...31

Setpoint 1 (NSET1−N1) (mapping to C0046)

C0396*

LONGWORD
process output data

Bit 0...15

Controller status word 1
(mapping of C0150)

For bus operation only

·

Reading of status word and output
frequency in a telegram from controller

·

In keypad: display only (hexadecimal)

Bit 16...31

Output frequency (MCTRL1−NOUT)
(mapping of C0050)

C0409

v

Configuration relay
output K2

Output of digital signals to relay K2

·

Relay output K2 only with 8200 vector
15 ... 90 kW

·

For operation with Application−I/O only
active as of version E82ZAFA...XXVx2x

^ 7−73

255

255

Not assigned (FIXED−FREE)

Digital signals possible for C0409 see C0415