15 parameter set management, 1 saving and copying parameter sets, Saving and copying parameter sets – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 162: Function library, Parameter set management
Function library
Parameter set management
7−91
L
EDB82MV752 EN 5.2
7.15
Parameter set management
7.15.1
Saving and copying parameter sets
Description
Management of the controller parameter sets. It is possible to
·
restore the Lenze setting and put the controller into the delivery state again.
·
save your own basic setting, e.g. the delivery state of the machine.
·
transfer parameter sets from the keypad to the controller or vice versa. The settings can thus
be easily copied between controllers.
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze
Selection
C0002*
s
uSEr
Parameter set
management
−19−
0
0
Ready
PAR1 ... PAR4:
·
Parameter sets of the controller
·
PAR1 ... PAR4 also contain parameters
for Standard−I/O, Application−I/O,
AS interface or system bus (CAN)
FPAR1:
·
Module−specific parameter set of the
fieldbus function modules INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
·
FPAR1 is saved in the function module
^ 7−91
Restorage of
default setting
1
Lenze setting
ð PAR1
Restorage of default setting in the selected
parameter set
2
Lenze setting
ð PAR2
3
Lenze setting
ð PAR3
4
Lenze setting
ð PAR4
31
Lenze setting
ð FPAR1
Restorage of default setting in the fieldbus
function module
61
Lenze setting
ð PAR1 + FPAR1
Restorage of default setting in the selected
parameter set of the controller and the
fieldbus function module
62
Lenze setting
ð PAR2 + FPAR1
63
Lenze setting
ð PAR3 + FPAR1
64
Lenze setting
ð PAR4 + FPAR1
C0002*
s
uSEr
(cont.)
Parameter set
transfer using the
keypad
Use the keypad to transfer parameter sets
to other controllers.
During transfer the parameters cannot
be accessed via other channels!
Keypad
ð Controller
All available parameter sets (PAR1 ... PAR4,
and FPAR1) are overwritten with the
corresponding keypad data
70
With function module Application−I/O, INTERBUS,
PROFIBUS−DP, LECOM−B, DeviceNet/CANopen
10
With all other function modules