Appendix, Code table – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 229
Appendix
Code table
14−28
L
EDB82MV752 EN 5.2
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0240
v
(A)
Process controller
output inversion
(PCTRL1−INV−ON)
(parameter
channel)
0
0
Not inverted
Set digital signal PCTRL1−INV−ON (process
controller output inversion) via keypad/PC or
parameter channel
1
Inverted
C0241
v
(A)
Process controller
not hidden/hidden
(PCTRL1−FADING)
(parameter
channel)
0
0
Process controller unhiding
Set digital signal PCTRL1−FADING (process
controller hiding/unhiding) via keypad/PC or
parameter channel
1
Process controller hiding
C0242
v
(A)
Activation of
process controller
inverse control
0
0
Normal control
Act. value increases
ð Output frequency
increases
1
Inverse control
Act. value increases
ð Output frequency
decreases
C0243
v
(A)
Deactivation of
additional setpoint
(PCTRL1−NADD−OF
F) (parameter
channel)
0
0
PCTRL1−NADD active
Set digital signal PCTRL1−NADD−OFF
(deactivation of additional setpoint) via
keypad/PC or parameter channel
1
PCTRL1−NADD not active
C0244
v
(A)
Root function actual
process controller
value
0
0
not active
1
" | PCTRL1−ACT |
Ǹ
Internal calculation
1. Storing sign of PCTRL1−ACT
2. Extraction of the root of the absolute
value
3. Multiply the result with the sign
C0245*
v
(A)
Comparison value
for MSET1=MACT
0
0
MCTRL1−MSET (C0412/6 or C0047)
Selection of a comparison value for setting
the digital output signal MSET1=MACT
(torque threshold 1 = actual torque value)
·
If the difference between
MCTRL1−MSET1 and MCTRL1−MACT or
C0250 is within C0252:
– MSET1=MACT = HIGH after time set
under C0254
1
Value under C0250