Appendix, Code table – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 229

background image

Appendix

Code table

14−28

L

EDB82MV752 EN 5.2

Code

IMPORTANT

Possible settings

No.

Selection

Lenze

Name

C0240

v

(A)

Process controller
output inversion
(PCTRL1−INV−ON)
(parameter
channel)

0

0

Not inverted

Set digital signal PCTRL1−INV−ON (process
controller output inversion) via keypad/PC or
parameter channel

1

Inverted

C0241

v

(A)

Process controller
not hidden/hidden
(PCTRL1−FADING)
(parameter
channel)

0

0

Process controller unhiding

Set digital signal PCTRL1−FADING (process
controller hiding/unhiding) via keypad/PC or
parameter channel

1

Process controller hiding

C0242

v

(A)

Activation of
process controller
inverse control

0

0

Normal control

Act. value increases

ð Output frequency

increases

1

Inverse control

Act. value increases

ð Output frequency

decreases

C0243

v

(A)

Deactivation of
additional setpoint
(PCTRL1−NADD−OF
F) (parameter
channel)

0

0

PCTRL1−NADD active

Set digital signal PCTRL1−NADD−OFF
(deactivation of additional setpoint) via
keypad/PC or parameter channel

1

PCTRL1−NADD not active

C0244

v

(A)

Root function actual
process controller
value

0

0

not active

1

" | PCTRL1−ACT |

Ǹ

Internal calculation
1. Storing sign of PCTRL1−ACT
2. Extraction of the root of the absolute

value

3. Multiply the result with the sign

C0245*

v

(A)

Comparison value
for MSET1=MACT

0

0

MCTRL1−MSET (C0412/6 or C0047)

Selection of a comparison value for setting
the digital output signal MSET1=MACT
(torque threshold 1 = actual torque value)

·

If the difference between
MCTRL1−MSET1 and MCTRL1−MACT or
C0250 is within C0252:

– MSET1=MACT = HIGH after time set

under C0254

1

Value under C0250