2 rated data at a mains voltage of 230 v, 1 operation with rated power (normal operation), Rated data at a mains voltage of 230 v – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 20: Operation with rated power (normal operation), Technical data, Rated data at 230 v mains voltage
Technical data
Rated data at 230 V mains voltage
3−5
L
EDB82MV752 EN 5.2
3.2
Rated data at a mains voltage of 230 V
3.2.1
Operation with rated power (normal operation)
Typical motor power
Three−phase asynchronous motor
(4−pole)
P
N
[kW]
0.25
0.37
P
N
[hp]
0.34
0.5
8200 motec
Type
E82MV251_2B
E82MV371_2B
Mains voltage
U
mains
[V]
1/N/PE AC 180 V − 0 % ... 264 V + 0 % ;
45 Hz − 0 % ... 65 Hz + 0 %
Data for operation at 1/N/PE AC 230 V
Rated mains current
I
mains
[A]
3.4
5.0
Rated output current at
switching frequency
2 kHz
I
N24
[A]
2)
2.0
2.9
4 kHz
8 kHz
I
N8
[A]
1.7
2.4
16 kHz
I
N16
[A]
1.1
1.6
Max. permissible output
current for 60 s at
switching frequency
1)
2 kHz
I
max24
[A]
2.5
3.6
4 kHz
8 kHz
I
max8
[A]
2.5
3.6
16 kHz
I
max16
[A]
1.6
1.4
Output voltage
U
M
[V]
3~ 0 ... U
mains
/ 0 ... 650 Hz
Power loss (operation with I
N8
)
P
v
[W]
30
40
Dimensions
L x W x H [mm]
190 x 138 x 100
Weight
m [kg]
1.8
1.8
Bold print = data for operation at a switching frequency of 8 kHz (Lenze setting)
1)
Currents for periodic load change: 1 min overcurrent time with I
max
and 2 min base load time with 75 % I
Nx
2)
Under different operating conditions possible for some types: Operation with increased rated output current with the same load change
cycle (
Fuses and cable cross−sections
8200 motec
Normal operation
Installation acc. to EN 60204−1
Installation acc. to UL
1)
Type
System
Fuse
Circuit breaker
L1, L2, L3, PE
Fuse
L1, L2, L3, PE
FI
[kW]
[mm
2
]
[AWG]
E82MV251_2B
0.25
1/N/PE AC
180 ... 264 V;
45 ... 65 Hz
M10 A
C10 A
1.5
10 A
16
³ 30 mA
2)
E82MV371_2B
0.37
M10 A
C10 A
1.5
10 A
16
1)
Only use UL−approved cables, fuses, and fuse holders.
UL fuse: voltage 240 V, tripping characteristic "H", "K5" or "CC"
2)
Pulse current sensitive or universal−current sensitive earth−leakage circuit breaker
Observe national and regional regulations