beautypg.com

7 setpoints via a bus system, Setpoints via a bus system, Function library – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual

Page 117

background image

Function library

Configuration of analog and digital setpoints and actual values

7−46

L

EDB82MV752 EN 5.2

Setting tips

·

The setpoint via keypad has an effect on setpoint 1 (NSET1−N1) and setpoint 2 (NSET1−N2). If
you want to select different setpoints via keypad:
– Separate the linkage of NSET1−N1 and NSET1−N2 with analog input signals (C0412/1 = 0

and C0412/2 = 0).

– Now you can set NSET1−N1 in C0046 and NSET−N2 in C0044.

·

Set C0140 = 0 if the setpoint is not selected via C0140, otherwise the drive may start
immediately when the controller is enabled.

7.6.7

Setpoints via a bus system

Setpoints or actual values can be preselected for FIF by means of a bus function module or AIF by
means of a bus module.

A detailed description can be found in the documentation for the modules.