7 table of attributes, Appendix, Attribute table – Lenze 8200 motec frequency inverter 0.25kW-7.5kW User Manual
Page 252
Appendix
Attribute table
14−51
L
EDB82MV752 EN 5.2
14.7
Table of attributes
The data given in the table of attributes is required to write your own programs. It contains all
information for parameter communication with the controller.
How to read the table of attributes:
Column
Meaning
Entry
Code
Name of the Lenze code
Cxxxx
Index
dec
Index under which the parameter is
addressed The subindex of array variables
Is only required for control via INTERBUS,
PROFIBUS−DP or system bus (CAN)
hex
addressed. The subindex of array variables
corresponds to the Lenze subcode number.
PROFIBUS−DP or system bus (CAN).
Data
DS
Data structure
e
Single variable (only one parameter element)
a
Array variable (several parameter elements)
DT
Data type
B8
1 byte bit−coded
B16
2 bytes bit−coded
B32
4 bytes bit−coded
FIX32
32 bit value with sign;
decimal with four decimal positions
I32
4 bytes with sign
U32
4 bytes without sign
VS
ASCII string
Format
LECOM format
VD
ASCII decimal format
VH
ASCII hexadecimal format
VS
String format
VO
Octet string format for data blocks
DA
Number of array elements (subcodes)
XX
DL
Data length in bytes
Access
R/W Remote
Access authorisation for LECOM
Ra
Reading is always permitted
Wa
Writing is always permitted
w
Writing is attached to a condition
R/W CAN
Access authorisation for system bus (CAN)
Ra
Reading is always permitted
Wa
Writing is always permitted
w
Writing is attached to a condition
Condition
Condition for writing
CINH
Writing only permitted when controller is
inhibited