Appendix
Code table
14−17
L
EDB82MV752 EN 5.2
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0043*
v
TRIP reset
0
No current error
Reset active error with C0043 = 0
1
Active fault
C0044*
Setpoint 2
(NSET1−N2)
−650.00
{0.02 Hz}
650.00
The value set will be lost when
switching the mains!
·
Selection, if C0412/2 = FIXED−FREE (not
assigned)
·
Display if C0412/2 is linked with a signal
source
^ 7−45
C0046*
Setpoint 1
(NSET1−N1)
−650.00
{0.02 Hz}
650.00
The value set will be lost when
switching the mains!
·
Selection, if C0412/1 = FIXED−FREE (not
assigned)
·
Display if C0412/1 is linked with a signal
source
^ 7−45
C0047*
Torque setpoint or
torque limit value
(MCTRL1−MSET)
400
0
{1 %}
400
The value set will be lost when
switching the mains!
^ 7−10
Ref.: Rated motor torque detected by motor parameter
identification
Control mode "Sensorless torque control"
(C0014 = 5):
·
Torque setpoint selection if C0412/6 =
FIXED−FREE (not assigned)
·
Torque setpoint display if C0412/6 is
linked with a signal source
Control mode "V/f characteristic control" or
"Vector control" (C0014 = 2, 3, 4):
·
Torque limit value is displayed if
C0412/6 is linked with a signal source
·
C0047 = 400 is displayed if C0412/6 =
FIXED−FREE (not assigned)
C0049*
Additional setpoint
(PCTRL1−NADD)
−650.00
{0.02 Hz}
650.00
The value set will be lost when
switching the mains!
·
Selection, if C0412/3 = FIXED−FREE (not
assigned)
·
Display if C0412/3 is linked with a signal
source
C0050*
uSEr
Output frequency
(MCTRL1−NOUT)
−650.00
{Hz}
650.00 Only display: Output frequency without slip
compensation
C0051*
Output frequency
with slip
compensation
(MCTRL1−NOUT
+SLIP) or
act. process
controller value
(PCTRL1−ACT)
−650.00
{0.02 Hz}
650.00
The value set will be lost when
switching the mains!
Operation without process controller
(C0238 = 2):
·
Display only: Output frequency with slip
compensation (MCTRL1−NOUT+SLIP)
Operation with process controller
(C0238 = 0, 1):
·
Selection, if C0412/5 = FIXED−FREE (not
assigned)
·
Display if C0412/5 is linked with a signal
source
^ 7−54
C0052*
Motor voltage
(MCTRL1−VOLT)
0
{V}
1000 Only display
C0053*
DC−bus voltage
(MCTRL1−DCVOLT)
0
{V}
1000 Only display
C0054*
Apparent motor
current
(MCTRL1−IMOT)
0.0
{A}
2000.0 Only display
C0056*
Controller load
(MCTRL1−MOUT)
−255
{%}
255 Only display
Under C0311 you can change the display
value for the operating modes vector
control or sensorless torque control.