Toshiba Magnia 3030 User Manual
Page 80

Installing and Removing Hardware
Memory Module
62
NOTE: The suction fan module has two cable connectors, however, there is no
special order for connecting the two cables. Be careful not to mistake the
cable of the basic fan for that of the redundant one, or vice versa.
The basic suction fans and basic exhaust fan module are regarded as a set of
the basic fan configuration for this server, while the redundant suction fan and
redundant exhaust fan module are regarded as a set of the redundant fan
configuration.
8 Fit the panels to the server.
9 Connect the power cable of the server to the power supply and switch on the
server.
For the EPS-R model, switch on the server after turning on the DC operate
switch.
Memory Module
Maximum four 128/256/512 MB DIMM’s (Dual In-line Memory Modules)
with the ECC (Error Correction Control) can be installed in this server. (One
128 MB memory module is installed as the standard memory.)
See “Appendix A: Specifications” on page 197.
The memory can be expanded to a maximum of 2 GB by installing additional
memory modules with up to two different capacities.
The memory controller is conformable to the SDRAM. When installing addi-
tional memory modules, start from the lowest memory slot in numerical order,
namely from the slot 1 first, the slot 2 second, the slot 3 third and the slot 4 last.
When installing memory modules with different capacities, insert them in the
slots 1 to 4 in order of increasing capacity, that is, the memory module with the
smallest capacity in the slot 1.
PJ-9 FAN#1
PJ-10 FAN#2
PJ-11 FAN#3
PJ-12 FAN#4
PJ-13 FAN#5
PJ-14 FAN#6